Je suis sur ubuntu Precise Pangolin. Le processeur est Intel i3. un bureau.
J'ai installé lm-sensors
et ci-dessous est le rapport sensors
donné
coretemp-isa-0000
Adapter: ISA adapter
Core 0: +30.0°C (high = +89.0°C, crit = +105.0°C)
Core 2: +33.0°C (high = +89.0°C, crit = +105.0°C)
w83627dhg-isa-0a10
Adapter: ISA adapter
Vcore: +0.93 V (min = +0.00 V, max = +1.74 V)
in1: +0.75 V (min = +1.99 V, max = +1.99 V) ALARM
AVCC: +3.36 V (min = +2.98 V, max = +3.63 V)
+3.3V: +3.36 V (min = +2.98 V, max = +3.63 V)
in4: +1.30 V (min = +0.90 V, max = +1.77 V)
in5: +0.76 V (min = +1.15 V, max = +0.90 V) ALARM
in6: +1.06 V (min = +0.94 V, max = +2.03 V)
3VSB: +3.36 V (min = +2.98 V, max = +3.63 V)
Vbat: +3.36 V (min = +2.70 V, max = +3.30 V) ALARM
fan1: 0 RPM (min = 3515 RPM, div = 128) ALARM
fan2: 0 RPM (min = 10546 RPM, div = 128) ALARM
fan3: 0 RPM (min = 10546 RPM, div = 128) ALARM
fan5: 0 RPM (min = 10546 RPM, div = 128) ALARM
temp1: +39.0°C (high = -121.0°C, hyst = +9.0°C) ALARM sensor = diode
temp2: +39.0°C (high = +80.0°C, hyst = +75.0°C) sensor = diode
temp3: +127.0°C (high = +80.0°C, hyst = +75.0°C) ALARM sensor = thermistor
cpu0_vid: +2.050 V
intrusion0: OK
radeon-pci-0100
Adapter: PCI adapter
temp1: +70.5°C
Les capteurs des ventilateurs détectent 0 tr/min et certaines températures sont hors limites - les alarmes ci-dessus mais je ne le comprends pas très bien. Quelqu'un peut-il aider?
Il paraît que lm-sensors
obtient des données erronées. Essayez d'exécuter Sudo sensors-detect
premier. Lisez attentivement chaque sortie, sur la dernière question:
Do you want to add these lines automatically to /etc/modules? (yes/NO)
tapez: yes
+Enter, puis redémarrez. Voyez si quelque chose a changé.